UniFi Lab 02 PoE budget blowout
Lab complete. The Flex is inside its PoE budget at night and every device stays Connected.
Connected, within PoE budgetUniFi Lab 02 PoE budget blowout
Flex: over its power budget
Connected, within PoE budgetWiFi and cameras keep dropping off
Get every camera and access point powered at once.
Pick a different break
All steps
Tap a number
Before and after
Diff rows marked| Setting or symptom | Broken start | Now |
|---|
Injector class
Camera, Front door
On shows night draw. The budget uses the camera max either way.
Per-port PoE mode
About this lab
The settings you can change in this lab. Everything else is fixed.
Hints
Good to know · info only
Out of scope for this lab
This run: Injector too small. USW-Flex on PoE Adapter 15W, two APs and a camera, night.
Topology
Site: PoE lab, night- Gateway optionalData only in this lab. Feeds the injector LAN jack.Online
- LAN: data only, no PoEGateway to injector LAN jack.
- Injector Power runs short herePoE Adapter 15W
Class 802.3afInput ~15.4W inFlex budget about 8W
Injector too small for this load - Port 1, PoE in: 802.3af, about 8W downstream35.9W max needed. The link is up, the watts are not there.
- USW-Flex5 port switch, powered on Port 1, PoE out on 2 to 5USW-Flex
- Port
- 4
- Speed
- 1 GbE
- Link
- 1G
- PoE
- 4.6 W
- Device
- Camera, Front door
Max draw, what UniFi budgets35.9W of 8W, 27.9W over
Live draw, what you see now15.0W of 8W, 7.0W over
Exceeded total PoE budget - Ports 2, 3, 4: PoE outThe Flex cuts a port when the camera asks for its night watts.
- AP LobbyU7 Lite class access point, Port 2ConnectedAt risk on the next reboot
Live 5.4WMax 13.0W
- AP OfficeU7 Lite class access point, Port 3OfflineDropped when the camera rebooted
Live 0.0WMax 13.0W
Offline - Camera, Front doorG6 Bullet class Protect camera, Port 4OfflinePort cut, reboot loop
Live 0.0WMax 9.9W
IR on, nightOffline
Legend
- Power and data, inside budget
- Power runs short on this link
- Data only, no PoE
- Connected or allowed
- Offline or over budget
- Warning, not a win
PoE insights
USW-Flex, ports 2 to 5Input: Port 1 from PoE Adapter 15W, 802.3af. Downstream budget about 8W.
| Port | Device | Mode | Live | Max |
|---|---|---|---|---|
| 2 | AP LobbyConnected | Auto | 5.4W | 13.0W |
| 3 | AP OfficeOffline | Auto | 0.0W | 13.0W |
| 4 | CameraOffline, IR on | Auto | 0.0W | 9.9W |
| 5 | Empty | Auto | 0.0W | 0.0W |
| Total | 15.0W | 35.9W | ||
| Downstream budget | 8W | |||
| Headroom at max | 27.9W over | |||
Live is what the device draws right now. Max is the documented maximum UniFi budgets for, camera IR on. Watt values are example numbers for teaching.
Why it broke Broken and Fixed
Try another way this breaks
Why this fails
AF injector on a loaded Flex
USW-Flex has exceeded total of 8W. This can cause device disconnects. Please offload devices to new switch or PoE Injector.
Field note: Daytime draw looks fine. UniFi budgets the max each PD can take. An AF injector starves the Flex. Here that is 35.9W max against about 8W out.
Fix: Swap to Adapter 60W. Offloading only the camera still leaves two APs, about 26W, over an 8W or 20W .
Cameras jump watts when IR turns on
AP Office: Offline. Camera, Front door: Offline
Field note: Cameras jump watts when IR turns on. Budget for night, not noon. When the Flex runs short a port drops, the device reboots, and the boot draw can knock the next one off.
Fix: Fix the budget. Turning IR off is not a fix.
Read more: PoE Availability and Modes (opens in a new tab) (Ubiquiti Help Center)
Console words
- has exceeded total Showing: 35.9W , 8W budget
- This can cause device disconnectsHappening now
- OfflineShowing: AP Office, Camera
- Connected1 of 3, at risk on reboot
Glossary
Core, Labs 01 to 03- Native VLAN
- The untagged VLAN on a switch port. UniFi device management usually rides here. Set as Native VLAN in Port Manager.
- Tagged VLAN Management
- Port setting for which VLANs ride tagged (802.1Q): Allow All, Block All, or Custom. Guest and IoT SSIDs need their VLANs tagged on the AP uplink.
- Access port
- One VLAN only, untagged. Fine for a printer. Wrong for an AP that serves multiple SSIDs.
- Trunk
- A port carrying the Native VLAN plus tagged VLANs. The right setup from switch to AP, or switch to gateway, when there are several networks.
- ZBF
- Zone-Based Firewall. Rules are set between zones, like Internal, External, Gateway and Hotspot, plus custom zones such as IoT.
- Gateway zone
- The router itself, which answers DHCP and DNS. Block a network's zone from the Gateway and its clients get no IP or DNS.
- Client Device Isolation
- WiFi setting that stops guest clients on the same AP from talking to each other. Keep it on for Guest.
- PoE class
- AF (about 15W), AT (about 30W), BT / PoE++ (higher). UniFi budgets on documented max draw, not quiet daytime watts.
- PoE budget
- Every device's max draw added up, compared with what the switch or injector can supply. Go over it and devices lose power.
- Injector
- A box that adds PoE power to a cable. Too weak a class, like an AF injector on a loaded Flex, is a common field mistake.
- Max draw
- The most watts a device can pull, from its datasheet (IR on, at boot). UniFi PoE budgets use this, not the quieter live reading.
- Flex budget
- USW-Flex downstream totals by input: AF 8W, AT 20W, BT or 60W injector 46W (set Power Source to PoE Injector).
- Remote Unlock via Endpoint
- Access setting. When off, Endpoint receivers can talk on a call but cannot unlock.
- Door Attendant / receiver
- User assigned to get the door call. Not on the list means no Unlock for that door.
- Inform
- Device check-in URL to the Network application, usually controller host on port 8080, path /inform.
- STUN
- UDP 3478. Part of the required ports for device adoption and communication. set-inform still needs TCP 8080 to the Network host.
- set-inform
- Device SSH command that tells a UniFi device where its Network host is, e.g. http://192.168.1.10:8080/inform.
- Pending Adoption
- Devices list state for a device that has checked in and is waiting for you to click Adopt.
- Managed by Other
- Devices list state. Another instance of UniFi Network owns the device, including the same console after a factory restore. Fix: restore a backup, factory reset and re-adopt, or reassign in the mobile app.
- Device SSH Settings
- Network setting holding the SSH login an adopted device uses. Factory default devices use ui / ui (ubnt / ubnt on older devices).
- Debug Console
- Built-in browser shell on the console.
- DHCP Option 43
- DHCP option that hands devices the Network host address so they adopt across VLANs.
Fiber terms, glossary ready for later
MM and SM grades, cage form factors, DAC, AOC, and complementary BiDi ends. Full rows land with the fiber-sfp-dac lab.
Symptom words (overlay language)
Gear in this lab
- 1 Gateway (optional)
- 1 Injector, PoE Adapter 15W
- 1 USW-Flex
- 2 Access points
- 1 Protect camera
This fix needs different hardware, not a setting. Counts only, no prices.
Takeaway
Budget for night, not noon
Daytime watts look fine on a Flex until the camera turns IR on or everything reboots at once. UniFi budgets the documented max of every powered device, so size the Flex input for that number.
- Add up the of every AP and camera, IR on.
- Match the Flex input to it. Two APs and a camera need Adapter 60W, not an AF .
- Plan around about 46W out from a 60W injector. That is the switch, not a broken adapter.
- Still tight? Move the camera to another PoE switch. On this lab, that alone does not clear an AT budget.
BOM delta on win
| Item | Broken start | After fix | Change |
|---|---|---|---|
| Injector, PoE Adapter 15W (802.3af) | 1 | 0 | Remove 1 |
| Injector, PoE++ Adapter 60W | 0 | 1 | Add 1 |
| USW-Flex | 1 | 1 | No change |
| Access points | 2 | 2 | No change |
| Protect camera | 1 | 1 | No change |
Offloading the camera onto an AT injector still fails here. Two APs are 26.0W max against a 20W Flex budget. PoE++ Adapter 60W, about 46W out, is the clean fix. Counts only, no prices.
Want APs and cameras powered like this at your place? We size PoE budgets and install Protect cameras as part of a UniFi install.
USW-Flex has exceeded total PoE budget of 8W. This can cause device disconnects. Please offload devices to new switch or PoE Injector.
A teaching lab, not a quote and not a design for your site. Watt values are simplified examples from the UniFi Network app PoE view. No account, and nothing from this lab is saved.